          The quality of survival, technology and development
          Quality for survival, technology for development
          LSKM6 Prepaid circuit breaker
          LSKM6 Prepaid circuit breaker
          LSKM6 Prepaid circuit breaker

          LSKM6 series electric energy meter external circuit breaker is an automatic reclosing miniature circuit breaker specially designed for communication and electric power with the function of automatic tripping and closing.The breaker is applicable to the line of  AC 50Hz, rated voltage to 400V, rated current to 125A, mainly used with cost control electric energy meter. It not only can solve the problem that the power supply cannot be automatically restored after the switch trips due to arrears, and realize the function of “remote control”, it can also protect the electrical equipment and the line according to the current short circuit and overload operation of the power supply line.

          The breaker meets the standards GB 10963.1-2005 and QGDW11421-2015, etc.

           

          Technical Parameters

          Wiring

          1P+N、2P  single-phase

          3P+N、4P  Three-phase four-wire system

          Rated voltage Ue

          AC 230V 1P+N、2P

          AC 400V 3P+N、4P)  

          Rack rated currentInm

          80A、125A

          Rated currentIn

          6A、10A、16A、20A、25A、32A、40A、50A、63A、80A、100A、125A

          Control signal

          AC 230V

          Electric operation assembly method

          Left or right

          Standby power consumption

          Control signal line leakage current1mA;

          Phase line leakage current0.2mA

          Automatic closing timetc

          tc3s

          Power-on delaytd

          7std8s  (SG and CSG);4std5s  (CQC);customizable

          Mechanical life

          10000 times

          Electrical life

          6000 times

          Overload short circuit protection

          C type5In-10In

          Rated limit short-circuit breaking capacityIcn

          S type6000A;H type10000A

          Rated insulation voltageUi

          500V

          Dielectric strength

          AC 2500V  1min

          Impulse withstand voltageUimp

          6kV

          IP grade

          IP20

          Operating temperature

          -40~ 70

          Pollution level

          2

          Action process

          Refer to state control table 2

          Humidity

          The maximum temperature is no more than 50% at +40, and higher relative humidity at lower temperatures, such as 90% at +20.

          Special measures should be taken for condensation that occasionally occurs due to temperature changes.

          Conversion operation

          Pull the switch to the automatic position. After the arrears are automatically opened, the charging will be automatically closed. If the electrical line fails, it can be manually closed.

          Pull the switch to the manual position. After the arrears are automatically opened, the charging will not be automatically closed, and manual closing is required.

          Status Indicator

          The indicator light is on, indicating that the meter is not owed, and can be divided and closed normally;

          The indicator light is off, indicating that the meter cannot be closed or the line is dead.

          Feedback function

          Remotely query operational status

          Product details
          TG网